CITY OF SANTA MONICA
CITY
PLANNING DIVISION
DATE: October 21, 2002
TO: Architectural
Review Board
FROM: Planning Staff
SUBJECT: ARB 02-036, 133 Fraser Avenue:
Single-Family Residence
Approval of
Building Design, Colors, and Materials
APPLICANT: Jill
Soffer
PROPERTY OWNER: Jill
Soffer
INTRODUCTION
The applicant requests Architectural
Review Board approval for the proposed design of a 390-square foot master
bedroom and bathroom addition to an existing single-family residence.
Recommendation
Approve with conditions.
Zoning District / Relevant Specific
Plans or Guidelines
R2R (Low Density Duplex) District /
None.
Historic Resources Inventory
Designation
Properties
in the South Beach Tract, including the subject property, are listed on the
City’s Historic Resources Inventory as a Class 5D1 (not eligible for the
National Register, but appears to be a contributing structure to a potential
local historic district, the South Beach Historic District). An historic
evaluation indicates that most of the buildings along Fraser Avenue are not
individually historically significant; it is however, the scale and character
of the beach cottages as a whole that are potentially significant.
Although
the circa 1901 building retains its overall design, its façade materials have
been changed over time. The wood siding
has been replaced by stucco, the open front porch has been enclosed, and many
of the windows have been replaced. Overall, the design of the proposed second
story addition respects the historic significance of the existing house. Although staff is concerned with some of the
design details such as the stucco and cable balcony railing and roof eaves,
staff believes that the proposed project would not adversely affect the ability
to designate this area as a historic district in the future.
The proposed project is categorically
exempt from the provisions of the California Environmental Quality Act (CEQA)
pursuant to Section 15301(e)(1) of the State Guidelines in that the project
involves the construction of a second story, 390 square foot addition to a
single family dwelling which constitutes a 29% increase in floor area to the
existing structure.
Relevant Permit History / Prior Action
(ARB)
01VAR-022: A
Variance allowing a reduction in the number of garage parking spaces and
allowing the roof eves to project into the side yard was approved on November
9, 2001.
DESIGN
REVIEW
Building Design
|
DESIGN ELEMENTS |
PROPOSED EXTERIOR MATERIAL, FINISH AND COLOR |
|
Façade |
Stucco
(Aspen) Wood
trim (Bone China) |
|
Windows |
Wood
Frame Awning Windows below sofit |
|
Doors |
Wood
Frame French Doors w/ clear glass |
|
Roof |
Asphalt
Shingles (Ebonywood) |
|
Railings |
Horizontal
Stainless Steel Cables between 42” high Stucco Walls on Balcony |
STAFF
ANALYSIS
The existing 1,333 square foot single
family home is located on a 35’-3” wide by 94’-3” (3,418 square foot) lot. The
existing residence is set back 10’ from the Fraser Avenue property line. The immediate area is developed with a mix
of one and two story single-family homes and apartments.
The proposed second story addition will
provide a new master bedroom and bathroom, adding 390 square feet to the
existing two-bedroom single family home.
The project also includes an 87 square foot roof deck on the west side
of the bedroom addition. The addition
will be set back approximately 9’ from the front of the existing house and will
retain the existing hip roof over the single-story portion. The second story
will have a hip roof with the same pitch as the existing building. In-lieu of the flared eaves and open rafter
tails, the addition will incorporate a sofit eave design. A single row of windows will encircle the
addition just below the ceiling/sofit.
French doors and matching side windows provide clear glazing along the
width of the roof deck. The roof deck
is enclosed by a 3’-6” high stucco parapet and a rail consisting of horizontal
stainless steel cables.
The project has been reviewed for
compliance with applicable regulations and it complies. Variance 01-022
approved the expansion of the single-family home with a one-car garage and one
tandem parking space in-lieu of a two-car garage. Variance 01-022 also allowed
the roof eaves to encroach into the side yard setback. However, the Building Code prohibits roof
eaves from being closer than two feet (2’) to a property line. Although Variance 01-022 allows the eaves to
project 16” from the property line, a condition has been added which requires
compliance with all pertinent regulations, including the Building Code. Accordingly, the eaves on the east side can
extend only 2’ into the side yard.
A significant number of structures on
this block have retained the charm and character of the Beach Bungalow
neighborhood that was established in the early 1900’s. The size, location, and
overall design of the proposed addition complement the existing circa 1901
building, maintaining a desirable architectural character while allowing for
the addition. The off-white stucco walls and trim will match the existing
building colors and materials. However,
staff is concerned with the proposed steel cable railing and believes that a
wood handrail with decorative spindles or balusters on the roof deck would be
more appropriate.
RECOMMENDATION
Planning staff recommends that the
Architectural Review Board approve ARB application 02-036 based upon the
following findings and subject to the conditions below:
FINDINGS:
A.
The plan for the proposed building or structure is
expressive of good taste, good design, and in general contributes to the image
of Santa Monica as a place of beauty, creativity and individuality in that the
size, location, and overall design of the proposed addition, including the hip
roof and front and side stepbacks, complement the existing circa 1901 building.
B.
The proposed building or structure is not of inferior
quality such as to cause the nature of the local neighborhood or environment to
materially depreciate in appearance and value in that high quality material as
detailed in the application submittal and as presented to the Architectural
Review Board will be used.
C.
The proposed design of the building or structure is
compatible with developments on land in the general area in that design of the
proposed addition complements the existing circa 1901 building which is
compatible with the mix of one and two-story, bungalow style single-family
homes and apartments in the South Beach neighborhood.
D.
The proposed
development conforms to the effective guidelines and standards adopted pursuant
to Chapter 9.32 – Architectural Review Board, and all other applicable
ordinances. Specifically, the location and appearance of the buildings and
structures comply with required findings set forth in Chapter 9.32, as
documented by the Architectural Review Board, and the plan has demonstrated compliance
with all applicable ordinances as reviewed by staff and documented in VAR
01-022 and ZC 01-010.
CONDITION(S):
1.
This approval shall expire when the administrative or
discretionary entitlements previously granted by an associated approval have
lapsed. If no such permit has been issued, this approval shall expire one year
from its effective date, unless appealed or otherwise implemented pursuant to
applicable municipal regulations.
2.
The applicant shall
comply with all other provisions of Chapter 1, Article IX of the Municipal Code
(Zoning Ordinance) and all other pertinent ordinances and General Plan policies
of the City of Santa Monica.
Attachments:
Applicant’s Submittal Material